Welcome to QET, where innovation meets precision in laboratory equipments! As a leading provider in the field, we take pride in offering cutting edge solutions to meet the diverse the needs of modern laboratories. Our commitment to excellence, reliability, and customer satisfaction sets us apart in the world of laboratory equipment trading.

365_ Insulation Tester

Features:

  • Insulation Test Range Up To 20GΩ
  • Test Voltages Of 50V, 100V, 250V, 500V and 1000V For Insulation Test
  • >1mA Short-Circuit Test Current For Insulation Test
  • Live Circuit Detection
  • Open Circuit Test Voltage > 4V and Short-Circuit Current > 200mA For LoΩ Test
  • Power Source: Size AA Batteries (IEC LR6) x 4pcs
  • Auto Power Off: Approx. 10 minutes
  • Approvals: EN61010 600V CAT IV
  • Electromagnetic Compatibility: EN61326-1
  • Battery: 1.5V size AA battery x 4
  • Dimensions: 206x90x51 mm
  • Weight: 510g
  • Insulation Rresistance Measurement

    Insulation test voltage Range Accuracy
    50V 300KΩ/3.00MΩ/30.0MΩ/300MΩ/1.00GΩ ±(3%rdg+5dgts) (30KΩ~1.00GΩ)
    100V 600KΩ/6.00MΩ/60.0MΩ/600MΩ/2.00GΩ ±(3%rdg+5dgts) (60KΩ~2.00GΩ)
    250V 1.50MΩ/15.0MΩ/150MΩ/1.50GΩ 5.0GΩ ±(3%rdg+5dgts) (0.15MΩ~1.50GΩ) ±(10%rdg+3dgts)
    500V 3.00MΩ/30.0MΩ/300MΩ/3.00GΩ 10.0GΩ ±(3%rdg+5dgts) (0.30MΩ~3.00GΩ) ±(10%rdg+3dgts)
    1000V 6.00MΩ/60.0MΩ/600MΩ/6.00GΩ 20.0GΩ ±(3%rdg+5dgts) (0.60MΩ~6.00GΩ) ±(10%rdg+3dgts)

    AC/DC Voltage

    Range Resolution Accuracy (AC: 45~500Hz) Protection
    60.00V/600.0V 0.01V/0.1V ±2%rdg+5dgts 600Vrms

    Resistance

    Range Resolution Accuracy Protection
    600.0Ω/6.000KΩ/60.00ΚΩ/600.0ΚΩ 0.1Ω/0.001KΩ/0.01ΚΩ/0.1ΚΩ 2%rdg+5dgts 600Vrms

    Continuity

    Range Resolution Accuracy Protection
    600.0Ω 0.1Ω ≦ 7Ω±1Ω 600Vrms

    LoΩ

    Range Resolution Accuracy
    6.00Ω/60.0Ω 0.01Ω/0.1Ω 2%rdg+3dgts